Availability: | |
---|---|
Quantity: | |
Product Description
SENSING INPUT | Voltage | 190-264V ac | ||||||||
Frequency | 50-61 Hz nominal | |||||||||
phase | 1 | |||||||||
Wire | 2 | |||||||||
OUTPUT | Voltage | max 90V dc at 207V ac input | ||||||||
Current | continuous 4A dc, intermittent 6A for 10 secs | |||||||||
Resistance | 15 ohms minimum | |||||||||
REGULATION | +/- 1.0% | |||||||||
THERMAL DRIFT | 0.04% per deg. C change in AVR ambient | |||||||||
TYPICAL SYSTEM RESPONSE | AVR response | 20ms | ||||||||
Filed current to 90% | 80 mS | |||||||||
Machine Volts to 97% | 300 mS | |||||||||
EXTERNAL VOLTAGE ADJUSTMENT | ’+/-10% with 1 k ohm 1 watt trimmer | |||||||||
UNDER FREQUENCY PROTECTION | Set point | 95% Hz | ||||||||
Slope | 170% down to 30 Hz | |||||||||
UNIT POWER DISSIPATION | 12 watts maximum | |||||||||
BUILD UP VOLTAGE | 4 Volts @ AVR terminals | |||||||||
ANALOGUE INPUT | Maximum input | +/- 5 Vdc | ||||||||
Sensitivity | 1v for 5% | |||||||||
Input resistance | 1k ohm | |||||||||
QUADRATURE DROOP INPUT | 10 ohms burden | |||||||||
Max. sensitivity: 0.07 A for 5% droop 0PF | ||||||||||
Max. input: 0.33A | ||||||||||
ENVIRONMENTAL | Vibration | 20-100 Hz,50mm/se | ||||||||
100Hz - 2kHz, 3.3g | ||||||||||
Operating temperature | -40 to +70 Deg. C | |||||||||
Relative Humidity 0-70 Deg. C | 95% | |||||||||
Storage temperature | -55 to +80 Deg. C |